Adaptation of Latex Diagnosis Parameters Determination using Multiplate Reader and Freeze-Drying Conservation to Support Large-Scale Utilization in Rubber Plantations

Junaidi, Junaidi and Syafaah, Afdholiatus and Aji, Martini and Ismawanto, Sigit and Oktavia, Fetrina and Subandiyah, Siti and Montoro, Pascal and Nuringtyas, Tri Rini (2024) Adaptation of Latex Diagnosis Parameters Determination using Multiplate Reader and Freeze-Drying Conservation to Support Large-Scale Utilization in Rubber Plantations. Trends in Sciences, 21 (9). 1 -15. ISSN 27740226

[thumbnail of 7963-Article Text for Production-27935-1-10-20240916.pdf] Text
7963-Article Text for Production-27935-1-10-20240916.pdf - Published Version
Restricted to Registered users only

Download (650kB) | Request a copy

Abstract

The Latex Diagnosis (LD) is performed through the determination of dry rubber (DRC), sucrose (Suc), inorganic phosphorus (Pi) and thiol (RSH) contents. It is carried out through the colorimetric method using a single cuvette spectrophotometer, which is time-consuming and requires a high volume of chemicals. It also needs to be executed as soon as the samples are collected so that limits the adoption of LD. The adaptation of the protocol to a multiplate reader and suitable conservation aimed to overcome the limitations. The experiments were carried out at the Indonesian Rubber Research Institute, Sembawa, Palembang, and Research Center for Biotechnology, Universitas Gadjah Mada, Yogyakarta. Various combinations of solution volumes, adapted from standard protocol, were tested. The closest slope of the standard curve to control was then applied to 7 randomly selected trees. The result showed that for Suc, the composition of 10 µL samples, 30 µL of 2.5 TCA and 210 µL anthrone reagent was suitable for determination using a multiplate reader. The combination of 40 µL of sample, 85 µL of 2.5 TCA and 125 µL mL FeSO4 solution was suitable for Pi determination, while 100 µL samples, 5 µL DNTB and 100 µL Tris is recommended for RSH. The measurement using a multiplate reader resulted in comparable contents (average deviations were 1.83, 2.69 and 3.51 for Suc, Pi, and RSH, respectively), lower time and chemicals consumptions, and a larger number of sample handling compared to single cuvette method. This study also tested the effect of freeze-drying for sample conservation. The result indicated that freeze-drying was able to maintain the Pi level (deviation 0.93 ). However, it increased Suc (deviation 19.43 ) and decreased ascorbate (AsA) significantly (deviation 43.60 ); therefore, freeze-drying might not be suitable for conserving serum samples in the LD method. © 2024, Walailak University. All rights reserved.

Item Type: Article
Additional Information: Cited by: 0; All Open Access, Green Open Access
Uncontrolled Keywords: Hevea brasiliensis, Latex diagnosis, Sucrose, Inorganic phosphorus, Thiols, Ascorbate, Multiplate reader, Freeze-drying
Subjects: Biology
Divisions: Faculty of Biology > Doctoral Program in Biology
Depositing User: Rusna Nur Aini Aini
Date Deposited: 30 Mar 2026 06:40
Last Modified: 30 Mar 2026 06:40
URI: https://ir.lib.ugm.ac.id/id/eprint/19492

Actions (login required)

View Item
View Item