Effectiveness of the Attachment Design and Thickness of Clear Aligners during Orthodontic Anterior Retraction: Finite Element Analysis

Alhasyimi, Ananto Ali and Ayub, Aulia and Farmasyanti, Cendrawasih Andusyana (2024) Effectiveness of the Attachment Design and Thickness of Clear Aligners during Orthodontic Anterior Retraction: Finite Element Analysis. EUROPEAN JOURNAL OF DENTISTRY, 18 (01). pp. 174-181. ISSN 1305-7456

[thumbnail of s-0043-1761452.pdf] Text
s-0043-1761452.pdf - Published Version
Restricted to Registered users only

Download (2MB) | Request a copy

Abstract

Objective Clear aligner treatment (CAT) provides orthodontic patients with a comfortable treatment alternative; however, this device has limited capacity to facilitate tooth movements. Although composite attachment has been proposed to facilitate tooth displacement, some of its aspects, such as aligner thickness, can influence CAT's precision. This work aimed to compare the stress distribution patterns produced by clear aligners with different thicknesses and composite attachment shapes during anterior retraction.
Materials and Methods Maxillary models consisting of clear aligners, maxillary teeth, and various attachments to the upper central incisor's labial surface were generated. Three models were built to mimic the retraction of the upper central incisors. Each had a distinct attachment design (rectangular attachment, ellipsoid attachment, and pyramidal attachment) and various aligner thicknesses (0.75, 0.85, 0.95, 1.05, and 1.15 mm). Upper central incisor retraction was accomplished using clear aligners. Finite element analysis was used to examine the built models. Stress distribution pattern was examined.
Results The greater the thickness of the aligner, the higher the stress experienced by the teeth. The 0.75 mm-thick aligner induces the lightest stress with a minimum of 0.0037623 MPa and a maximum of 0.32859 MPa. Meanwhile, the 1.5 mm-thick aligner has the highest stress with a minimum of 0.004679 MPa and a maximum of 0.43858 MPa. The force distribution on rectangular attachments appears evenly distributed. The maximum pressure force on rectangular attachments has a minimum of 0.38828 MPa, which is smaller than the maximum on ellipsoid and pyramidal attachments at 0.40933 and 0.45099 MPa, respectively.
Conclusion The best aligner thickness is 0.75 to 0.85 mm for anterior retraction. An aligner with 0.95 mm thickness can still be used when a remarkable amount of tooth movement force is needed; however, this exception is only applicable to a limited number of clear aligner trays. The ellipsoid attachment is the best type of attachment because the resulting force is substantial and evenly distributed.

Item Type: Article
Uncontrolled Keywords: attachment; clear aligner; force; orthodontic; retraction; thickness