Santoso, Marsha S. and Arguni, Eggi and Rana, Bunga and Adiniko, Mercy E. and Denis, Dionisius and Supriyati, Endah and Indriani, Citra and Trianty, Leily and Ahmad, Riris Andono and Noviyanti, Rintis and Tedjo Sasmono, R. (2025) Sensitivity and Specificity of an All-in-one Cartridge-based Dengue Real-time Reverse Transcription-PCR for Point-of-care Detection and Serotyping of Dengue Virus in Samples from Indonesian Patients. Annals of Laboratory Medicine, 45 (5). 503 - 508. ISSN 22343806
706.pdf - Published Version
Restricted to Registered users only
Available under License Creative Commons Attribution.
Download (253kB) | Request a copy
Abstract
Background: Dengue is a systemic, viral, mosquito-borne infection that continues to be a major public health issue in endemic regions in tropical and subtropical climates. Accurate tests for rapid diagnosis in point-of-care settings are important to reduce the fatality rates of severe dengue. We evaluated the diagnostic accuracy of the Standard M10 DENV 1-4 system (SD Biosensor, Gyeonggi, Korea), which is a cartridge-based, automated system that integrates nucleic acid extraction, reverse transcription-PCR (RT-PCR) amplification, and detection of dengue virus (DENV) serotypes. Methods: This was a retrospective diagnostic evaluation study. The index test, Standard M10 DENV 1-4, was evaluated using 320 dengue-positive and 279 dengue-negative archived samples. The reference tests were a combination of Centers for Disease Control and Prevention (CDC) DENV 1-4 real-time RT-PCR, dengue NS1 antigen and IgM antibody detection, and DENV whole-genome sequencing. Results: The overall sensitivity and specificity of Standard M10 DENV 1-4 were 94 and 100, respectively. By serotype, the highest sensitivity was 100 for DENV-1, and the lowest was 82 for DENV-4. The overall between the CDC RT-PCR dengue serotyping method and the Standard M10 DENV 1-4 was 95. Standard M10 DENV 1-4 RT-PCR had comparable sensitivity and specificity to CDC DENV RT-PCR. Conclusions: Based on its commensurate performance to an established RT-PCR method combined with additional benefits of convenient storage and transport, easy use, and rapid processing, the Standard M10 DENV 1-4 system has potential for DENV detection and serotyping in point-of-care settings. © Korean Society for Laboratory Medicine.
| Item Type: | Article |
|---|---|
| Additional Information: | Cited by: 1; All Open Access; Gold Open Access; Green Open Access |
| Uncontrolled Keywords: | Antibodies, Viral; Dengue; Dengue Virus; Humans; Immunoglobulin M; Indonesia; Point-of-Care Systems; Real-Time Polymerase Chain Reaction; Retrospective Studies; Reverse Transcriptase Polymerase Chain Reaction; RNA, Viral; Sensitivity and Specificity; Serotyping; Viral Nonstructural Proteins; immunoglobulin M; serotyping; viral nonstructural protein; virus antibody; virus RNA; blood; classification; dengue; Dengue virus; diagnosis; genetics; human; immunology; Indonesia; isolation and purification; point of care system; procedures; real time polymerase chain reaction; retrospective study; reverse transcription polymerase chain reaction; sensitivity and specificity; virology |
| Subjects: | R Medicine > RB Biomedical Sciences |
| Divisions: | Faculty of Medicine, Public Health and Nursing > Biomedical Sciences |
| Depositing User: | Mukhotib Mukhotib |
| Date Deposited: | 12 Aug 2026 02:27 |
| Last Modified: | 12 Aug 2026 02:27 |
| URI: | https://ir.lib.ugm.ac.id/id/eprint/28675 |