Comparing the performance of three modalities of breast cancer screening within a combined programme targeting at-risk women in Indonesia: An implementation study

Choridah, Lina and Icanervilia, Ajeng Viska and Rengganis, Anggraeni Ayu and At Thobari, Jarir and Postma, Maarten J. and D.I. van Asselt, Antoinette (2023) Comparing the performance of three modalities of breast cancer screening within a combined programme targeting at-risk women in Indonesia: An implementation study. Global Public Health, 18 (1). ISSN 17441692

[thumbnail of 362.pdf] Text
362.pdf - Published Version
Restricted to Registered users only
Available under License Creative Commons Attribution.

Download (1MB) | Request a copy

Abstract

Although mammography is the gold standard for breast cancer screening, the World Health Organization recommends clinical breast examination (CBE) as the preferred early detection method in countries with limited resources. However, its effectiveness as a ‘stand-alone’ screening modality compared with other techniques remains unclear. Therefore, we evaluated a risk-based opportunistic breast cancer screening programme using three modalities. Between June and December 2018, we conducted a cross-sectional study in Yogyakarta, Indonesia, of women aged >40 years with at least one risk factor for breast cancer. Subjects underwent CBE, mammography, and ultrasonography. We calculated the proportion of breast lesions detected through each modality and compared their mass size. A total of 503 eligible subjects were screened. Five cases of potential malignant lesions were detected; pathological tests conducted for 4 of them confirmed breast cancer diagnoses. A combined assessment of mammography and ultrasonography examinations revealed 343 breast lesions (68.2), whereas CBE screening detected only 76 breast lesions (15.1). The mean lesion sizes detected by mammography or ultrasonography, but not through CBE, were significantly smaller (p-values of 0.037 and 0.007 for mammography and ultrasonography, respectively). In conclusion, mammography and ultrasonography produced higher detection rates for benign and malignant breast lesions compared with CBE.

Item Type: Article
Additional Information: Library Dosen
Uncontrolled Keywords: Breast cancer; screening; mammography; ultrasonography; clinical breast examination
Subjects: R Medicine > RC Internal medicine > RC0254 Neoplasms. Tumors. Oncology (including Cancer)
Divisions: Faculty of Medicine, Public Health and Nursing > Public Health and Nutrition
Depositing User: Mukhotib Mukhotib
Date Deposited: 23 Aug 2024 01:29
Last Modified: 23 Aug 2024 01:29
URI: https://ir.lib.ugm.ac.id/id/eprint/2868

Actions (login required)

View Item
View Item