Non-Contact Electric Field May Induced Higher CD4, CD8, Caspase-8, and Caspase-9 Protein Expression in Breast Tumor Tissue of Rats (Rattus norvegicus Berkenhout, 1769)

Nuriliani, Ardaning and Nurhidayat, Luthfi and Fatmasari, Hindana and Afina, Dalila and Alamsyah, Firman and Taruno, Warsito Purwo and Pratiwi, Rarastoeti (2024) Non-Contact Electric Field May Induced Higher CD4, CD8, Caspase-8, and Caspase-9 Protein Expression in Breast Tumor Tissue of Rats (Rattus norvegicus Berkenhout, 1769). Malaysian Journal of Fundamental and Applied Sciences, 20 (1). 74 – 88. ISSN 2289-5981

[thumbnail of 7_3065_(74-88).pdf] Text
7_3065_(74-88).pdf - Published Version
Restricted to Registered users only
Available under License Creative Commons Attribution Non-commercial.

Download (1MB) | Request a copy

Abstract

Non-contactelectric field therapy has been studied as one of less invasive and safe alternative methodsin cancer therapy. Some studies reported that non-contact electric fieldtherapy with low intensity (50 -60 V/m) and medium frequency (150 kHz) could slower the rat’s breast tumor growth and did not cause significant damage on the rat's kidney and liver. However, further study needed to evaluate the potency of non-contact electric field to be developed into effective cancer therapy. Thus, we investigated the immune response of non-contact electric field therapy through the detection of CD4 and CD8 protein expression and the mechanism of apoptosis through the detection of caspase-8 and caspase-9 proteins on breast tumor tissue of rats. Twenty four rats were divided into 4 groups: 1. non-induction -non-therapy (NINT), 2. non-induction -therapy (NIT), 3. induction -non-therapy (INT), and 4. induction -therapy (IT). DMBA (7,12-dimethylbenz(α)anthracene) 20 mg/kg body weight was used to induce breast tumor formation.Rats with breast nodules that had reached 1 cm in size were exposed to an ECCT device with 150 kHz and 50 -60 V/m electric fields. Further, the breast tissueswere collectedfor routine histological and immunohistochemistry preparation for CD4, CD8, caspase 8, as well as caspase 9 detection. The data were statistically analyzed using the Mann-Whitney U-Test method, with a significance level of p < 0.05 using the SPSS 16.0 version. The scoring results were compared between the INT and IT groups. Our results showed that non-contact electric field therapy could suppress breast tumor growth and improve its histological structure. Interestingly, the breast tissue of IT group qualitatively had slightly more necrotic and apoptotic cells than that of INT group. Moreover, the IT group showed higher CD4 and CD8 as well as higher caspase 8 and caspase 9 expression. Collecting all the data together, we concluded that non-contact electric field therapy potent to improve histological structure of breast tumo

Item Type: Article
Additional Information: Cited by: 1; All Open Access, Gold Open Access
Uncontrolled Keywords: Non-contact electric field, immunity, apoptosis, breast tumor, Rattus norvegicus
Subjects: Q Science > QH Natural history > QH301 Biology
Divisions: Faculty of Biology > Undergratuate Program in Biology
Depositing User: Ekowati Purwandari Purwandari
Date Deposited: 19 Sep 2024 02:11
Last Modified: 19 Sep 2024 02:11
URI: https://ir.lib.ugm.ac.id/id/eprint/6404

Actions (login required)

View Item
View Item