Effect of current and initial ph on electrocoagulation in treating the distillery spent wash with very high pollutant content

Syaichurrozi, Iqbal and Sarto, Sarto and Sediawan, Wahyudi Budi and Hidayat, Muslikhin (2021) Effect of current and initial ph on electrocoagulation in treating the distillery spent wash with very high pollutant content. Water (Switzerland), 13 (1). ISSN 20734441

[thumbnail of water-13-00011.pdf] Text
water-13-00011.pdf
Restricted to Registered users only

Download (3MB) | Request a copy

Abstract

The distillery spent wash (DSW) from bioethanol industries has a very high chemical oxygen demand (COD). Hence, the goal of this study is to investigate the effect of currents (2.5, 3 and 3.5 A) and initial pHs (4.4, 5.0 and 7.0) on electrocoagulation (EC) to decrease the COD in DSW. The results showed that the EC at the current of 3.5 A enabled a higher COD removal efficiency (74.9) than those at the currents of 2.5 (35.4) and 3 A (60.9). Furthermore, the initial pH of 7.0 resulted in a higher COD removal efficiency than the initial pHs of 4.4 and 5.0. The solution pH and temperature increased throughout the process. The working volume was not constant due to the reactions of water reduction, evaporation and flotation. Scum and sludge productions were also monitored during the process. Then, the measured data (COD, sludge and scum) were used in the modeling. The simple mechanistic models were successfully built and applied to simulate the data in mass units with two different routes of process. Route 1 assumed that the COD was converted to sludge and then the latter was converted to scum. Route 2 assumed that the COD was converted to the sludge and scum at the same time. When the EC was operated at the initial pH of 4.4, the COD removal process followed route 1, but that at the initial pHs of 5.0 and 7.0, the COD removal process followed route 2. The higher the current applied in the EC, the higher the kinetic constants of ka and kb . Additionally, the higher the initial pH set, the higher the kinetic constants were. This showed that the formation rates of sludge and scum at the higher currents or initial pHs were faster than those at the lower values.

Item Type: Article
Additional Information: Library Dosen
Uncontrolled Keywords: current; distillery spent wash; electrocoagulation; initial pH; kinetic; high pollutant content
Subjects: T Technology > TP Chemical technology > Chemical engineering
Divisions: Faculty of Engineering > Chemistry Engineering Department
Depositing User: Sri JUNANDI
Date Deposited: 29 Oct 2024 06:44
Last Modified: 29 Oct 2024 06:44
URI: https://ir.lib.ugm.ac.id/id/eprint/5956

Actions (login required)

View Item
View Item