Mathematical model of astaxanthin purification process using the low-pressure column chromatography method

Dewati, P.R. and Rochmadi, R and Rohman, A. and Budiman, A. (2023) Mathematical model of astaxanthin purification process using the low-pressure column chromatography method. South African Journal of Chemical Engineering, 45. pp. 256-268. ISSN 10269185

[thumbnail of Mathematical model of astaxanthin purification process.pdf] Text
Mathematical model of astaxanthin purification process.pdf - Published Version
Restricted to Registered users only

Download (7MB) | Request a copy

Abstract

Astaxanthin is an antioxidant compound that can be extracted from the microalgae Haematococcus pluvialis using the microwave-assisted extraction (MAE) method. Purification of the astaxanthin compound can be conducted using a low-pressure column chromatography (LPCC) method. However, the mathematical model illustrating the adsorption and desorption process using the LPCC method has not been built by the other authors yet. Therefore, the purposes of this study were (1) to build the mathematical model of the purification process using the LPCC method, and (2) to simulate the experimental data using the model to find the important kinetic constant values that can be used in the industrial scale-up in the future. The purification process was carried out with silica gel as a stationary phase and a mixture of n-hexane:acetone of 3:1 (v/v) as a mobile phase. The silica gel diameter was varied to 0.2�0.5 mm and 0.063�0.2 mm, while the eluent velocity was varied to 1.85 mL/min and 3 mL/min. The mathematical model having five kinetic constants of De1, De2, kc2, kc2.a, and HA2 was successfully built. The De1 and De2 (m2/s) were the effective diffusivities of astaxanthin in the intraparticle direction of the adsorbent granule and in the axial direction of the column, respectively. The kc2 (m/s) was the mass transfer coefficient of astaxanthin from the solution to the adsorbent. The kc2.a (/s) was the volumetric mass transfer coefficient of astaxanthin from the solution to the adsorbent. The HA2 (g silica gel/m3) was the Henry's constant for astaxanthin concentration at equilibrium at the liquid-solid interface. In the variation of silica gel diameter, the De2 value at the diameter of 0.2�0.5 mm was greater than that at 0.063�0.2 mm. However, the De1, kc2, kc2.a, and HA2 values ��were not affected by the different diameters. In the variation of eluent velocity, the kc2 and kc2.a values at 3 mL/min were greater than those at 1.85 mL/min. However, the De1, De2, and HA2 values were not affected by the different eluent velocities. © 2023 The Authors

Item Type: Article
Additional Information: cited By 1
Uncontrolled Keywords: Astaxanthin; Mathematical model; Low-pressure column; chromatography; Purification
Subjects: R Medicine > RS Pharmacy and materia medica
T Technology > TP Chemical technology > Chemical engineering
Divisions: Faculty of Pharmacy
Depositing User: Pujoko PUJOKO
Date Deposited: 18 Sep 2024 05:26
Last Modified: 18 Sep 2024 05:26
URI: https://ir.lib.ugm.ac.id/id/eprint/7014

Actions (login required)

View Item
View Item